Certified Protection:
Engineered to meet international standards (e.g., EN 16034, UL 10B/C), with fire ratings from 1 to 4 hours (Class A per GB14102).
Critical Applications:
Warehouse Partitioning, Prevent fire from spreading across storage zones
Manufacturing Facilities, Protect machinery & hazardous materials
Logistics Centers, Secure loading bays while maintaining accessibility
Power Plants & Chemical Storage, Extra protection for high-risk areas
e.g. For Warehouses & Storage Facilities
Minimize fire risks and secure high-value inventory with industrial-grade fireproof shutters. Our solutions are certified for fire resistance, heat insulation, and forced-entry protection, ensuring business continuity and asset safety. Custom sizes, remote operation and 24/7 reliability make them the smart choice for warehouses.
Why Choose Us?
✔ Tested & Certified – Meets international fire safety standards
✔ Durable & Low-Maintenance – Long-lasting performance
✔ Custom Solutions – Tailored to your space and needs
✔ Automated or Manual Options – For convenience and security
Invest in Safety Today! Contact us for a FREE consultation and fire risk assessment.
Fire Rated Rolling Door Price
Characteristics
MULTIPLE ACTIVATION MODES
SMOKE SEALING: INFLATABLE OR BRUSH SEALS EXPAND UNDER HEAT TO BLOCK TOXIC SMOKE (MEETING EN 12101-3 FOR SMOKE CONTROL).
SAFETY SENSORS: INFRARED OR PHOTOELECTRIC SENSORS PREVENT ACCIDENTAL CLOSURE ON OBSTACLES.
AESTHETIC OPTIONS
STANDARD COLORS (RAL CODES) OR CUSTOM PRINTS TO BLEND WITH ARCHITECTURAL THEMES. FOLDABLE LIFT-TYPE VARIANTS (E.G., U-SHAPED, CURVED) FIT IRREGULAR OPENINGS WITHOUT SUPPORT COLUMNS, MAXIMIZING ARCHITECTURAL FLEXIBILITY.
SUPERIOR FIRE RESISTANCE
NO WATER PROTECTION NEEDED, UNLIKE TRADITIONAL STEEL SHUTTERS, INORGANIC COMPOSITE SHUTTERS ELIMINATE THE NEED FOR WATER SPRAY SYSTEMS, SAVING WATER AND REDUCING INFRASTRUCTURE COSTS.
Certification Standard
EN16034: the overarching standard for pedestrian and industrial fire/smoke doors & shutters. it mandates assessment against:
EN 1634-1: fire resistance test for doors, shutters, and operable fabric curtains (integrity, insulation)
EN 1364-2: fire resistance tests for non-loadbearing elements - part 2: ceilings (relevant for shutter boxes/cassettes).
EN 1363-1/2: general fire resistance test methods.
EN 13501-2: classification using test data from above
UL 10B / UL 10C: standard fire tests for door assemblies.
UL 263: standard for fire tests of building construction and materials (similar scope to ASTM 119).
Technical data
FIRE RATING | > or =3–4 HOURS (TESTED TO GB9978/EN 1634) | TYPES, APPLICATIONS & BENEFIT | |
BACKFACE TEMPERATURE | AVG. > or =380°C; MAX. SINGLE POINT > or = 180°C | ① DUAL-TRACK DUAL-CURTAIN | |
CURTAIN THICKNESS | 10–20 MM (MULTI-LAYER: CERAMIC FIBER + FIREPROOF CLOTH) | LARGE MALLS, ATRIUMS, INDUSTRIAL ZONES | |
OPERATION SPEED | 2.5–6.4 M/MIN (ELECTRIC); 4–5 M/MIN (GRAVITY FALL) | AIR-LAYER INSULATION; NO WATER SPRAY | |
AIR GAP (DUAL CURTAINS) | 300 MM (OPTIMIZES THERMAL INSULATION) | ② WATER-MIST STEEL SHUTTER | |
SOUND INSULATION | UP TO 42 DB REDUCTION | HIGH-HUMIDITY AREAS (E.G., PARKING GARAGES) | |
MOTOR POWER | 0.25–1.5 KW (AC/DC OPTIONS) | RAPID COOLING; SMOKE SUPPRESSION | |
MAX. DIMENSIONS | WIDTH: < or = 60 FT (18.3 M); HEIGHT: < or = 40 FT (12.2 M) | ③ FOLDABLE LIFT-TYPE | |
STRUCTURAL REQUIREMENTS | IRREGULAR OPENINGS (E.G., ESCALATORS, CURVED WALLS) | ||
WALL STRENGTH | MUST SUPPORT 300–500 KG LOADS; CONCRETE/BRICK WALLS RECOMMENDED. | SPACE-SAVING; COLUMN-FREE DESIGN | |
OPENING TOLERANCE | ≤5 MM DEVIATION (PLUMB/LEVEL) FOR SEAMLESS TRACK ALIGNMENT. | ④ INSULATED STEEL (FIRESTAR) | |
APPLICATION | BUILDING PROJECT, COMPANY, HOME, OFFICE, HOTEL, CHURCH, JUST ANYWHERE YOU WANT! | EXTREME CLIMATES (E.G., COLD STORAGE) | |
PACKAGE | INSIDE: PE PAPER | OUTSIDE: DOUBLE LAYERS CARTON BOX AND WOODEN PALLETS. | MINERAL WOOL CORE; U-VALUE < or = 0.8 W/M²K |
Doors Overviews
RELATED SOLUTIONS